Description: FAQ1. What battery cables do I need to connect my charge controller and battery?A: Connect your charge controller to the battery with Renogy high-quality coppers tray cable. Specialized with battery rings on one end for effortless connection to your battery and exposed wire on the other end to lead directly into your charge controller, this wire makes the system set up as easy as can be!2. What wire size should my battery cables be?A: Consider the following factors when sizing your wire:Current flow in amps. Pick a wire gauge that is big enough to carry the amount of current (in amps) that will be flowing through your system. For instance, if you have Renogy 40Amp charge controllers, we would recommend using 8AWG wires.Charge controller terminals. Some charge controllers have small terminals that won’t accept wire thicker than a certain gauge. Check to see if compatible wire gauges are listed in your charge controller’s manual.3 Do I need to have the fuse between the charge controller and battery?A: When hooking up your Renogy system, the best way to add protection is by using fuses or circuit breakers. Fuses and circuit breakers are used to protect the wiring from getting too hot and also protect all devices connected in the system from catching fire or getting damaged if a short circuit occurs. They are not necessary for the system to run properly, but we always recommend using fuses or circuit breakers for safety purposes.There are three different locations that we recommend installing fuses or breakers: first, between the charge controller and battery bank, second, between the charge controller and solar panels, and third would be between the battery bank and inverter.To determine the fuse size needed between the charge controller and battery bank you simply match the amperage rating on the charge controller. For instance, if you have Renogy 40Amp charge controllers, we would recommend using a 40Amp fuse.STEP 1Materials & Tools Ready.Solar Charge ControllerBatteryBattery Cables (with terminal rings on one end and stripped at the other)Fuse Set with CableWire Crimper and screwsdriverSTEP 2Connect the Cable with Charge Controller.Insert the stripped end and fasten the terminal shut. All Renogy Charge Controllers have the battery terminals labeled with a battery icon “BATT".STEP 3Connect the Fuse to the Positive Battery Cable.The Renogy ANL fuse will protect the charge controller, wire, and battery from over-current. The fuse set and fuse cable are available from Renogy.STEP 4Connect the Battery Cables to the Battery.Connect the negative battery cable to the negative battery terminal and the positive cable to the positive terminal.STEP 5Charge Controller Turn On Now.Check the installation instructions in your charge controller’s manual and set up the battery type correctly.STEP 6Double Check All Your Connections.Make sure that none are loose.
Price: 10.89 USD
Location: Ontario, California
End Time: 2024-12-01T03:25:03.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Brand: Renogy
Type: Tray Cables
Connector Style: Ring
Contact Material: Copper
MPN: RNG-TRAYCB-16FT-10-US
Material: Copper
Item Length: 16ft
Gauge: 10 AWG